Olympus Magna-Mike 8600 Thickness Gauge Things To Know Before You Buy

The Magna-Mike 8600 gauge has been successfully integrated into high-quality Handle systems to evaluate aerospace sections crafted from composites and nonferrous components.

The minimal thickness measurement for your offered place will normally occur when the material being calculated is perpendicular on the probe suggestion, as well as goal is centered over the top on the probe idea. Using the minimum amount seize aspect on the Magna-Mike 8600 gage will help seize the correct thickness while you’re maneuvering the part staying calculated.

The Seal Integrity Tester for pouches plays a important purpose in making certain the integrity of pouch packaging used for several merchandise. Detecting any opportunity leakage within the seals is vital to circumvent product or service spillage and preserve packaging integrity.

As shown in the above mentioned reference desk, undertaking a multipoint calibration increases the calibration curve and the general accuracy in the instrument it does not matter which focus on you’re working with. Whenever you carry out a basic calibration, the instrument only has four calibration details (Ball Off, Ball On, Slender Shim, Thick Shim) to implement with the calibration curve.

If an unknown focus on error message occurs all through calibration, it means that the gage is struggling to discover the target or concentrate on ball.

This good quality lab tests instrument makes certain outstanding repeatability of exam measurements on numerous take a look at samples, offering consistent and responsible benefits. It makes use of a magnetic area to carry out measurements by way of a Goal Ball, wire, or disk, making it functional for different purposes.

“No Probe” Every time a probe is linked to the Magna-Mike 8600 which concept appears, a failure from the identification circuit to the probe occurred.

No cost motion of target balls: Mainly because Hall Result gages evaluate the gap among the probe idea plus the goal, geometrical obstruction on the ball will induce inaccurate measurements.

The probe's Hall Impact sensor measures the space concerning the probe suggestion Olympus Magna-Mike 8600 Thickness Gauge Specifications and concentrate on ball. The measurements are immediately shown on the large color thickness display as an easy-to-read through electronic thickness studying.

The goal might be attracted to the probe suggestion by a magnetic subject. When the goal is within just variety, the Magna-Mike 8600 will start to Display screen thickness values offering the probe suggestion and concentrate on are each in connection with the fabric.

We propose executing a Q-Cal not less than once each 50 percent hour While using the concentrate on removed from the probe tip. Should the instrument is getting used in a region with quite a lot of interference, you could possibly select to improve how frequently you execute a Q-Cal.

Sorry, this web page will not be offered inside your country Let us know what you're looking for by filling out the shape down below.

In PROTOCOL, pick which distant command set the instrument takes advantage of for interaction: • MULTI-CHAR: Multi-character commands utilized for conversation with a computer utilizing the Magna-Mike 8600 multi-character commands. • Solitary CHAR: Solitary-character command Commonly utilised when an external plan is controlling the instrument by remotely sending commands to imitate keystroke.

Vanta handheld XRF analyzers for production QA/QC present really distinct material chemistry to quickly and accurately establish pure metals and alloy grades when material precision is essential.